Compare Products
Hide
VS
200GE access switch (one 200GE port split into two 100GE ports), and 400GE ZR/ZR+ optical modules for interconnection at the maximum distance of 120 km
48 x 100GE ports and 8 x 400GE ports
RG-S6580-24DC8QC24 x 200GE Optical Ports, 8 x 400GE Optical Ports
Hardware Specifications
System Specifications |
RG-S6580-48CQ8QC |
RG-S6580-24DC8QC |
Ports |
48 × 100GE ports (DSFP) + 8 × 400GE ports (QSFP-DD) |
24 × 200GE ports (QSFP56) + 8 × 400GE ports (QSFP-DD) |
Expansion Modules |
Not supported |
|
Expansion Module Slots |
Two power supply module slots (1+1 redundancy) Six fan module slots (5+1 redundancy; at least 5 fan modules are required) |
|
Management Port |
One management port, one console port, and one USB port, compliant with the USB2.0 standard |
|
Switching Capacity |
16.0 Tbps |
|
Packet Forwarding Rate |
5350 Mpps |
|
802.1Q VLAN |
4094 |
|
Dimensions |
||
Dimensions (W × D × H) |
442 mm x 700 mm x 44 mm (17.40 in. x 27.56 in. x 1.73 in., 1 RU) |
442 mm x 670.8 mm x 43.6 mm (17.40 in. x 26.41 in. x 1.72 in., 1 RU) |
Weight |
Chassis with six fan modules and two power supply modules: 11.5 kg (25.35 lbs.) |
Chassis with six fan modules and two power supply modules: 11 kg (24.25 lbs.) |
Power Supply and Consumption |
||
Power Input |
AC input RG-PA1200I-F module ● Rated voltage: 110 V AC/220 V AC ● Rated voltage range: 100 V AC to 127 V AC (50 Hz to 60 Hz), rated current: 13.8 A ● Rated voltage range: 200 V AC to 240 V AC (50 Hz to 60 Hz), rated current: 8.5 A ● Max voltage range: 90 V AC to 264 V AC (47 Hz to 63 Hz)
HVDC input RG-PA1200I-F module ● Rated voltage: 240 V DC ● Max voltage range: 180 V DC to 300 V DC ● Max input current: 6.5 A |
|
Maximum Power Consumption |
● Max: 742 W ● Typical: 633 W ● Static: 178 W |
● Max: 850 W ● Typical: 700 W ● Static: 300 W |
Environment and Reliability |
||
Temperature Alarm |
Temperature alarms and overheat protection |
|
Operating Temperature |
0ºC to 40ºC (32ºF to 104ºF) |
|
Storage Temperature |
–40°C to +70°C (–40ºF to +158ºF) |
|
Operating Humidity |
10% RH to 90% RH (non-condensing) |
|
Storage humidity |
5% to 95% RH (non-condensing) |
|
Working altitude |
Operating altitude: up to 5000 m (16,404.20 ft.) Storage altitude: up to 5000 m (16,404.20 ft.) |
Software Specifications
Software Specifications |
RG-S6580-48CQ8QC |
RG-S6580-24DC8QC |
L2 Protocols |
IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB) |
|
L3 Protocols (IPv4) |
BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP |
|
IPv6 Basic Protocols |
Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS |
|
IPv6 Features |
Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+ |
|
ACL |
ACL 80、ACL-based Redirection、IPv6 ACL、Extended/Standard IP/MAC-based ACL、Time-based ACL、Global ACL、When an ACL is applied to different physical interfaces or SVIs, resources can be shared.、ACL Counter、ACL Counter Only、ACL Logging、Diplaying ACL Resource Usage、Expert-level ACL、IPv4 UDF ACL、Global ACL Counter Only、Matching Against the Inner 5-Tuple of the VXLAN、IPv6 UDF ACL、Matching Against the Inner 5-Tuple of the Passing VXLAN、Ingress/Egress ACLs |
ACL80、ACL-based redirection、IPv6 ACL、Extended/Standard IP ACL、Extended MAC ACL、Time-based ACL、Global ACL、Resource sharing in the case of applying an ACL on different physical ports or SVIs、ACL counter、ACL counter only、ACL logging、Displaying ACL resource usage、ACL-based re-marking、Expert-level ACL、IPv4 user-defined function(UDF) ACL、Configuring ACL counter-only globally、ACL matching against the inner 5-tuple of VXLAN packets、IPv6 UDF ACL、ACL matching against the inner 5-tuple of packets passing through the VXLAN |
Data Center Features |
PFC, ECN, and other data center features RDMA |
|
Visualization |
gRPC sFlow sampling |
|
QoS |
Mapping of IEEE 802.1p, DSCP, and ToS priorities ACL-based traffic classification Priority marking/remarking Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR Congestion avoidance mechanisms such as WRED and tail discarding |
|
HA Design |
GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules |
|
Security Features |
Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management |
|
Management Mode |
SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm |
|
Other Protocols |
DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog |
Safety and Regulatory Compliance
Specifications |
RG-S6580-48CQ8QC |
RG-S6580-24DC8QC |
Safety |
● IEC 62368-1 ● EN 62368-1 ● BS EN 62368-1 ● GB 4943.1 |
● GB 4943.1 |
Electromagnetic Compatibility (EMC) |
● EN 55032 ● BS EN 55032 ● EN 55035 ● BS EN 55035 ● EN 61000-3-2 ● EN 61000-3-3 ● BS EN 61000-3-2 ● BS EN 61000-3-3 ● EN 300 386 ● GB/T 9254.1 |
● GB/T 9254.1 ● VCCI-CISPR 32:2016 |
Environment |
● 2011/65/EU EN 50581 ● 2012/19/EU EN 50419 ● (EC) No.1907/2006 ● GB/T 26572 |
● 2011/65/EU EN 50581 ● 2012/19/EU EN 50419 ● (EC) No.1907/2006 ● GB/T 26572 |
*For more country-specific regulatory information and approvals, contact your local sales agency.
The configuration procedure for RG-S6580 series switches is as follows:
Product Model |
Description |
RG-S6580-48CQ8QC |
48 × 100GE DSFP ports + 8 × 400GE QSFP-DD ports Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules. |
RG-S6580-24DC8QC |
24 × 200GE QSFP56 ports + 8 × 400GE QSFP-DD ports Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules. |
Product Model |
Description |
RG-PA1200I-F |
1200 W AC module (AC/240 V HVDC) |
Product Model |
Description |
M1HFAN II-F |
Fan module (front-to-rear ventilation) |
Product Model |
Description |
400G-QDD-SR8-MM850 |
400G SR8 module, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF |
400G-QDD-DR4-SM1310 |
400G DR4 module, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF |
400G-QDD-FR4-SM1310 |
400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
Product Model |
Description |
100G-AOC-5M |
100G QSFP28 AOC cable, 5 m (16.40 ft.) |
100G-AOC-10M |
100G QSFP28 AOC cable, 10 m (32.81 ft.) |
100G-QSFP-SR-MM850 |
100G SR module, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF |
100G-QSFP-iLR4-SM1310 |
100G iLR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
100G-QSFP-LR4-SM1310 |
100G LR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
100G-QSFP-ER4-SM1310 |
100G ER4 module, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Fale conosco
How can we help you?