Compare Products

Hide

Clear All

VS

Picture

RG-S6110-24MG4VS-UP – 24-Port 5G Managed Multi-GE Access Switches with 25G Uplink Ports

5G/2.5G/1G/100M access, PoE/PoE+/PoE++, 4 x 25G uplink optical ports, offering flexible networking options to build high-performance campus networks

Models
Series
Highlight Features
  • 24 x 5G/2.5G/1G/100M Base-T Ethernet ports and 4 x 25G uplink ports, meeting high bandwidth demands of large campuses
  • Multi-level hardware protection, ensuring continuous device operation and stable network connectivity
  • VSU, delivering flexible networking capabilities and high performance
  • Multiple network security policies and real-time monitoring, ensuring consistently high network performance
  • Intelligent fan speed adjustment and auto port sleeping, reducing power consumption and noises
  • Various network management methods, achieving simplified network maintenance
Sales Enquiry
Features

RG-S6110-24MG4VS-UP 5G Multi-GE Access Switches

Twenty-four service ports support 5G/2.5G/1G/100M access and four 25G uplink ports are provided to realize flexible networking.
High-power PoE++ is provided and a maximum of 90 W PoE power supply meets different terminal needs.

Port

Dimensions

Hardware Redundancy, Guaranteed Service Continuity and Network Connectivity

Hardware-Level Boot Redundancy

Optical Port Fault Isolation

Two Flash chips are used to store the system Boot program for hardware-level Boot redundancy, avoiding device failure caused by a failed Flash chip.

VSU Virtualization, Flexible Networking and High Performance

Millisecond Failover

High Scalability

Simplified Networking

Connected by an aggregate link, the VSU virtual system and peripherals switch links in milliseconds to ensure service continuity in case of a failure.

Network Security Policies and Real-Time Monitoring, Delivering Enhanced Network Robustness

CPP

NFPP

CPP protects the CPU from data attacks to ensure CPU stability under high usage, achieving significant improvement in the device's security performance.

Intelligent Speed Regulation and Auto Sleeping, Reducing Energy Consumption and Noise

Intelligent fan speed regulation based on monitored component temperatures, saving energy
Auto service port sleeping, reducing device power consumption.

Managed by the INC Controller to Achieve Easy and Efficient O&M Management

The switch automatically completes registration and configuration after it accesses the all-optical network, achieving plug and play, no commissioning and fast onboarding.
You can check the link health status, handle alarms and troubleshoot faults through the INC, which dramatically improves the O&M efficiency.
A switch can be flexibly replaced based on service needs without reconfiguration. Service ports supports auto-sensing, achieving automatic O&M.
Fast Onboarding Fast Onboarding
Optical Link O&M Optical Link O&M
Visualization Zero Touch Replacement
Specifications

Hardware Specifications

Hardware Specifications

RG-S6110-24MG4VS-UP

RG-S6110-48MG4VS2QXS-UP

 

RG-S6120-24XMG4XS4VS-UP-H

RG-S6120-48XMG4VS2QXS-UP-H

Interface Specifications

Fixed port

24 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation

4 x 10GE/25GE SFP28 ports

Ports 1 to 24 support PoE/PoE+ and HPoE power supply (maximum output power of a HPoE-capable port: 90 W)

48 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation

4 x 10GE/25GE SFP28 + 2 x 40GE QSFP+ ports

Ports 1 to 48 support PoE/PoE+ power supply (ports 1 to 24 support HPoE power supply, maximum output power of a HPoE-capable port: 90 W)

 

24 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation

4 x 10GE SFP+ ports 4 x 25GE SFP28 ports 

Ports 1 to 24 support PoE/PoE+ and HPoE power supply (maximum output power of a HPoE-capable port: 90 W)

48 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation

4 x 10GE/25GE SFP28 + 2 x 40GE QSFP+ ports

Ports 1 to 48 support PoE/PoE+ power supply (ports 1 to 24 support HPoE power supply, maximum output power of a HPoE-capable port: 90 W)

Fan module

2 x fixed fan modules

Fan speed regulating and fault alarms

3 x fan module slots

Fan speed regulating and fault alarms

 

3 x fan module slots

Fan speed regulating and fault alarms

3 x fan module slots

Fan speed regulating and fault alarms

Power module

1 x built-in power module

2 x power module slots

 

2 x power module slots

2 x power module slots

Fixed management port

1 x MGMT port, 1 x console port, and 1 x USB2.0 port

System Specifications

Packet forwarding rate

327 Mpps

625 Mpps

 

565 Mpps

982 Mpps

System switching capacity

440 Gbps

840 Gbps

 

760 Gbps

1320 Gbps

Number of MAC addresses

Number of global MAC addresses: 32,768

Number of static MAC addresses: 1,000

Number of global MAC addresses: 32,768

Number of static MAC addresses: 1,000

Number of global MAC addresses: 32,768

Number of static MAC addresses: 1,000

Number of global MAC addresses: 32,768

Number of static MAC addresses: 1,000

ARP table size

16,000

16,000

 

16,000

16,000

ND table size

4,000

4,000

 

4,000

4,000

Number of IPv4 unicast routes

16,000

16,000

 

16,000

16,000

Number of IPv4 multicast routes

4,000

4,000

 

4,000

4,000

Number of IPv6 unicast routes

16,000

16,000

 

16,000

16,000

Number of IPv6 multicast routes

2,000

2,000

 

2,000

2,000

Number of IGMP groups

4,000

Number of MLD groups

1,000

Number of ACEs

Ingress: 2,500

Egress: 1,000

Number of VSU members

2

2

 

2

2

Dimensions and Weight

Dimensions (W x D x H)

442 mm x 220 mm x 43.6 mm (17.40 in. x 8.66 in. x 1.72 in.)

442 mm x 420 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.)

 

442 mm x 420 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.)

442 mm x 420 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.)

Weight (chassis and fan modules)

3.65 kg (8.05 lbs)

6.11 kg (13.47 lbs)

 

6.11 kg (13.47 lbs)

6.11 kg (13.47 lbs)

CPU and Storage

CPU

1.2 GHz single-core processor

1.2 GHz single-core processor

 

1.2 GHz single-core processor

1.2 GHz single-core processor

Storage

1 GB DDR4

1 GB flash memory

2 GB DDR4

1 GB flash memory

 

1 GB DDR4

1 GB flash memory

2 GB DDR4

1 GB flash memory

Data packet buffer

4 MB

4 MB

 

4 MB

4 MB

Power and Consumption

Maximum power consumption

Without PoE: < 120 W

Full PoE load: < 370 W

Without PoE: < 240 W

Full PoE load: < 1,600 W

 

Without PoE: < 120 W

Full PoE load: < 1,650 W

Without PoE: < 240 W

Full PoE load: < 1,600 W

Maximum output power

Built-in power: 460 W (370 W for PoE output power supply and 90 W for the chassis)

RG-PA600I-P-F: 600 W (400 W/450 W for PoE output power supply and 150 W/200 W for the chassis)

RG-PA1000I-P-F: 1,000 W (800 W/850 W for PoE output power supply and 150 W/200 W for the chassis)

 

RG-PA600I-P-F: 600 W (400 W/450 W for PoE output power supply and 150 W/200 W for the chassis)

RG-PA1000I-P-F: 1,000 W (800 W/850 W for PoE output power supply and 150 W/200 W for the chassis)

RG-PA600I-P-F: 600 W (400 W/450 W for PoE output power supply and 150 W/200 W for the chassis)

RG-PA1000I-P-F: 1,000 W (800 W/850 W for PoE output power supply and 150 W/200 W for the chassis)

Rated input voltage

AC input: 100 V AC to 240 V AC

Frequency: 50/60 Hz

Rated current per circuit: 6 A

RG-PA600I-P-F:

● AC input: 100 V AC to 240 V AC

● Frequency: 50/60 Hz

● Rated current per circuit: 8 A

RG-PA1000I-P-F:

● AC input: 100 V AC to 240 V AC

● Frequency: 50/60 Hz

● Rated current per circuit: 8 A

 

Maximum input voltage

90 V AC to 264 V AC

Environment and Reliability

MTBF

22.18 years

27.02 years

 

22.18 years

27.02 years

Primary airflow

Front/Left-to-rear airflow

Front/Left-to-rear airflow

 

Front/Left-to-rear airflow

Front/Left-to-rear airflow

Operating temperature

0°C to 45°C (32°F to 113°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

10% to 90% RH (non-condensing)

Storage humidity

5% to 90% RH (non-condensing)

Operating altitude

–500 m to +3000 m (–1640.42 ft. to +9842.52 ft.)

–500 m to +3000 m (–1640.42 ft. to +9842.52 ft.)

 

–500 m to +3000 m (–1640.42 ft. to +9842.52 ft.)

–500 m to +3000 m (–1640.42 ft. to +9842.52 ft.)

Operating noise

Typical value: < 40 dBA@27°C (80.6°F)

Maximum value < 78 dBA

Typical value: < 60 dBA@27°C (80.6°F)

Maximum value < 78 dBA

 

Typical value: < 60 dBA@27°C (80.6°F)

Maximum value < 78 dBA

Typical value: < 60 dBA@27°C (80.6°F)

Maximum value < 78 dBA

Interface surge protection

6 kV

Software Specifications

RG-S6100 Series

Feature

Description

Ethernet switching

Jumbo frame (maximum length: 9,216 bytes)

IEEE 802.1Q (supporting 4K VLANs)

Maximum number of VLANs that can be created: 4,094

Voice VLAN

Super-VLAN and private VLAN

MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment

GVRP

Basic QinQ and selective QinQ

STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)

ERPS (G.8032)

LACP (IEEE 802.3ad)

LLDP/LLDP-MED

IP service

Static and dynamic ARP

DHCP server, DHCP client, DHCP relay, and DHCP snooping

DNS

DHCPv6 server, DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping

Neighbor Discovery (ND) and ND snooping

IP routing

Static routing

RIP and RIPng

OSPFv2 and OSPFv3

GR

IS-ISv4 and IS-ISv6

BGP4 and BGP4+

Equal and Weighted Cost Multi-Path (ECMP)

Packet-based and flow-based load balancing

Stateless Auto Configuration

IPv4/IPv6 VRF

IPv4/IPv6 PBR

Multicast

IGMPv1/v2/v3 and IGMP proxy

IGMPv1/v2/v3 snooping

IGMP filtering and IGMP fast leave

PIM-DM, PIM-SM, and PIM-SSM

PIM-SSM for IPv4 and IPv6

MSDP to achieve inter-domain multicast

MLDv1/v2

MLD snooping

MSDP

PIM-SMv6

Multicast source IP address check

Multicast source port check

Multicast querier

ACL and QoS

Standard IP ACLs (hardware ACLs based on IP addresses)

Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers)

Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type)

Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)

Time-based ACLs

ACL80 and IPv6 ACL

Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)

ACL redirection

Port traffic identification

Port traffic rate limiting

802.1p/DSCP/ToS traffic classification

Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences

Traffic classification based on ToS values

Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ

Congestion avoidance: tail drop, RED, and WRED

Eight queues on each port

Rate limiting in each queue

Security

Multi-AAA

RADIUS and TACAS+

Filtering of invalid MAC addresses

Broadcast storm suppression

Hierarchical management of administrators and password protection

BPDU guard

RADIUS authentication and authorization

Port- and MAC address-based 802.1x authentication

IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication

Web authentication

Hypertext Transfer Protocol Secure (HTTPS)

SSHv1 and SSHv2

Global IP-MAC binding

ICMPv6

Port security

IP source guard

SAVI

ARP spoofing prevention

CPP and NFPP

Various attack defense functions including NFPP, ARP anti-spoofing, DHCP/DHCPv6 attack defense, ICMP attack defense, ND attack defense, IP scanning attack defense, and customizing attack defense packet types

Loose and strict RPF

uRPF ignoring default routes

Reliability

REUP

ERPS (G.8032)

Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control

Data Link Detection Protocol (DLDP)

IPv4 VRRP v2/v3 and IPv6 VRRP

BFD

GR for RIP, OSPF, and BGP

Power modules in 1+1 redundancy mode

Hot swapping of power modules and fan modules (not supported by the RG-S6110-24MG4VS-UP)

Device virtualization

VSU

NMS and maintenance

SPAN, RSPAN, and ERSPAN

sFlow

NTP and SNTP

FTP and TFTP

SNMP v1/v2/c3

RMON (1, 2, 3, 9)

Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, as well as private alarm extension groups

RMON used to implement Ethernet statistics, historical statistics, and alarm functions

NETCONF

Flow-based mirroring, and N:1 and 1:N port mirroring

CWMP

gRPC

OpenFlow Special 1.3

Flow table analysis defined by all protocols

Transmission of specified packets to the controller

Configuring the controller's IP address and port

Notifying port status changes to the controller

CLI (Telnet/console), SSH, Syslog, SNMP over IPv6, Telnet v6, FTP/TFTP v6, DNS v6, and NTP for IPv6

Ruijie Could-based management

Note: The item marked with the asterisk (*) will be available in the future.

Show More
Order Information

Follow the steps to order an RG-S6100 multi-GE switch:

  • Select a model of RG-S6100 series switches. The device is fully equipped with fan modules that do not need to be purchased separately.
  • Select power modules based on switch models. At least one power module is required.
  • Select optical modules based on optical interfaces of the switch.

Models marked with asterisks (*) in Ordering Information will be available in the future.

The switch, expansion module, power module, and other components can be ordered as needed. Before ordering an expansion module or power module, contact the online customer service personnel for the latest support information about the module.

Switches and Power Modules

Model

Description

RG-S6110-24MG4VS-UP

24 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation

4 x 10GE/25GE SFP28 ports

RG-S6110-48MG4VS2QXS-UP

48 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation

4 x 10GE/25GE SFP28 + 2 x 40GE QSFP+ ports

RG-S6120-24XMG4XS4VS-UP-H

24 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation

4 x 10GE SFP+ ports 4 x 25GE SFP28 ports

RG-S6120-48XMG4VS2QXS-UP-H

48 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation

4 x 10GE/25GE SFP28 + 2 x 40GE QSFP+ ports

RG-PA600I-P-F

600 W AC power module

RG-PA1000I-P-F

1000 W AC power module

RG-PA150I-F

150 W AC power module

GE Optical Module

Model

Description

Mini-GBIC-GT

1000BASE-GT mini GBIC module

MINI-GBIC-SX-MM850

1000BASE-SX, SFP transceiver, SM (850 nm, 500 m, LC).

MINI-GBIC-LX-SM1310

1000BASE-LX, SFP transceiver, SM (1310 nm, 10 km, LC)

MINI-GBIC-LH40-SM1310

1000BASE-LH, SFP transceiver, SM (1310 nm, 40 km, LC)

MINI-GBIC-ZX80-SM1550

1000BASE-ZX80, SFP transceiver, SM (1550 nm, 80 km, LC)

GE-SFP-LX20-SM1310-BIDI

SFP BIDI Transceiver-TX1310/RX1550, 20 km, LC

GE-SFP-LX20-SM1550-BIDI

SFP BIDI Transceiver-TX1550/RX1310, 20 km, LC

GE-SFP-LH40-SM1310-BIDI

SFP BIDI Transceiver-TX1310/RX1550, 40 km, LC

GE-SFP-LH40-SM1550-BIDI

SFP BIDI Transceiver-TX1550/RX1310, 40 km, LC

10GE Optical Modules

Model

Description

XG-SFP-SR-MM850

10GE LC connector module, applicable to the SFP+ port

62.5 μm/125 μm: 33 m

50 μm/125 μm: 66 m

Modal bandwidth of 2000 MHz·km for a link length of up to 300 meters

XG-SFP-LR-SM1310

10GE LC connector module with a link length of up to 40 km, 1310-nm wavelength, applicable to the SFP+ port

XG-SFP-ER-SM1550

10GE LC connector module with a link length of up to 40 km, 1550-nm wavelength, applicable to the SFP+ port

XG-SFP-AOC1M

10GE SFP+ port cable, 1 m, including one cable and two interface modules

XG-SFP-AOC3M

10GE SFP+ port cable, 3 m, including one cable and two interface modules

XG-SFP-AOC5M

10GE SFP+ port cable, 5 m, including one cable and two interface modules

25GE Optical Modules

Model

Description

VG-SFP-SR-MM850

25GE SR, SFP28, 850-nm wavelength, 100 m over MMF

VG-SFP-LR-SM1310

25GE LR, SFP28, 1310-nm wavelength, 10 km over SMF

VG-SFP-AOC5M

25GE SFP+ active optical cable, 5 m, including two modules

40GE Optical Modules

Model

Description

40G-QSFP-SR-MM850

40GE SR, QSFP+ transceiver, applicable to QSFP+ ports

OM3 and OM4 MMF, MPO, 8-core, 850-nm wavelength, 100 m over OM3 MMF or 150 m over OM4 MMF

40G-QSFP-LR4 SM1310

40GE LR4, QSFP+ transceiver, LC, 1310-nm wavelength, 2-core, 10 km over SMF, applicable to QSFP+ ports

40G-AOC-5M

40GE QSFP+ active optical cable, 5 m, including one cable and two interface modules

40G-AOC-10M

40GE QSFP+ active optical cable, 10 m, including one cable and two interface modules

Show More
Perguntas frequentes Ask a Question
Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Fale conosco

Fale conosco

How can we help you?

Fale conosco

Get an Order help

Fale conosco

Get a tech support

2024 Ruijie Networks Brand Awareness Survey

Your opinions and feelings are crucial for our improvement.

Fill in the survey